Schließen Zurück Alle Abschnitte einklappen
Prozess-Datensatz: Prefix PP16mm rør Halogenfri (de) en

Kerninformationen des Datensatzes
Ort NO
Erläuterungen zur geographischen Repräsentativität Nordic
Referenzjahr 2025
Name
Prefix PP16mm rør Halogenfri
Anwendungshinweis für Datensatz Cradle to Gate. The following stages have been declared: A1-A4
Technisches Anwendungsgebiet Prefix pre-wired corrugated, Halogen free pliable / self-recovering conduit acc. to EN 61386-1 and EN 61386-22. Halogenfree KNX/EIB cable for transmission of BUS signals in intelegent building management systems based on standards of the Europeing Informatiin BUS EIB. Signals received from system sensors (Lighting, temperature, air conditioning, access control and others) are gathered in the EIB bus, and subsequently processed and used to control a device's operation. . The screen mimimizes EMC effects as susceptibility to noise and reduction of frequency emission. KNX: Worldvide standard for home and building control. EIB: Europaing Installation Bus. Halogen-free pipe and cables offer enhanced protection against smoke and toxid gases developed during fire. Products fulfils requirements of norms concerning quantity of toxic chemical compounds giving off during combustion. EN50575 CPR Class Dca CONDUIT Construction standards EN 611386-1; EN 61386-22 ICTA 34423 CABLE Construction - Factory standard
Klassifizierung
Klassenname : Hierarchieebene
  • EPDNorge: Construction / Electronic and electrical components and products
Allgemeine Anmerkungen zum Datensatz Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Data from material supplier and the LCA generator has been accepted "As-Is" Data from processing TECCON in-house has been repeated ongoingly without major deviations. Figures given in document are worst case values. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. The allocation is made in accordance with the guidelines given in EN 15804. Raw material - Information derived from manufactory and from a LCA generator Processing: Derived from actual measurements during production of the individual units/stages. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances. All major materials have been included. Substance representing <1% have not been included. This include folio film for packaging!
Copyright Ja
Eigentümer des Datensatzes
Quantitative Referenz
Referenzfluss(flüsse)
Biogener Kohlenstoffanteil
  • Innhold av biogent karbon i produkt: 0.0 kg
  • Innhold av biogent karbon i emballasjen: 0.013577981642 kg
Zeitliche Repräsentativität
Datensatz gültig bis 2030
Erläuterungen zur zeitlichen Repräsentativität 2025-04-29 - 2030-04-29
Technologische Repräsentativität
Technische Beschreibung inklusive der Hintergrundsysteme Corrugated Conduit Pliable/Self recovering halogen free Polypropylene Compression force 750N Marking EN, Date, and meter marking: 0-100m Temperature - operation -25 to + 90°C Temperature - installation -5 to + 90°C Bending Radius 8 x D Resistant to fire performance Flame retardant, self-extinguishing, low smoke toxic emission Insulations resistance >100M? at 500V in 1 min Test - mechanical Acc. EN 61386-1; EN 61386-22 Test - electrical Acc. EN 61386-1; >2,0kV 50HZ in 15 min CABLE Construction standards Factory Standard Conductor Single annealed cooper wire with diameter 0,8 mm. EN60228 Insulation - conductor Coloured special PE, nominal thickness 0,40 mm. Conductor marking 1. Red-Black 2. White-Yellow Conductor laying Cores twisted in Quad Screen Aluminium backed polyester tape with tinned copper drain wire Ø 0,4mm placed longitudinally under the screen Jacket Green halogen free, fire retardant og self extinguishing Marking «KNX/E-BUS» LSZH Bitner EB0005 E-Bus 2x2x0,8mm Ce RoHs Voltage - norminel Uo/U 800V Voltage - test - 1min/5min 4000/2500 Max capacitance par 100nF/km (conductor-conductor) Max conductor resistance v/ 20°C : 73,2 Ohm/km Resistance insulation 100MOhm.km Resistant to fire performance EN60332-1 CPR EN 50575 compliance Dca s1, d0, a1 DoP 17_0025_00 Temperature - operation -30 to 80 °C Temperature - installation -50 to 50 °C

Parameter zur Beschreibung des Ressourceneinsatzes und sonstige Umweltinformationen

IndikatorRichtungEinheit Rohstoffbereitstellung
A1
Transport
A2
Herstellung
A3
Transport
A4
Einbau
A5
Abbruch
C1
Transport
C2
Abfallbehandlung
C3
Beseitigung
C4
Recyclingpotential
D
Input
  • 0.08707
  • 0.002044
  • 0.01329
  • 0.001642
  • 0.7078
  • 0
  • 0
  • 0.0005363
  • 0.0004512
  • -2.757
Input
  • 0.8093
  • 0
  • 0
  • 0
  • -0.7932
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.8964
  • 0.002044
  • 0.01329
  • 0.001642
  • -0.0854
  • 0
  • 0
  • 0.0005362
  • 0.0004512
  • -2.757
Input
  • 2.584
  • 0.1428
  • 0.001469
  • 0.1147
  • 48.94
  • 0
  • 0
  • 0.01787
  • 0.00771
  • -1.067
Input
  • 1.556
  • 0
  • 0
  • 0
  • 0.002942
  • 0
  • 0
  • -1.541
  • 0
  • -0.3023
Input
  • 4.14
  • 0.1428
  • 0.001469
  • 0.1147
  • 48.94
  • 0
  • 0
  • -1.523
  • 0.007711
  • -1.369
Input
  • 0.0005536
  • 0
  • 0
  • 0
  • 0.0001023
  • 0
  • 0
  • 0
  • 0.000008987
  • 0.008809
Input
  • 0.007167
  • 0.00007311
  • 0.00001072
  • 0.00005873
  • 0.02527
  • 0
  • 0
  • 0.00001488
  • 0.00001004
  • -0.0002541
Input
  • 0.002321
  • 0.0002614
  • 0.00002711
  • 0.00021
  • 0.08955
  • 0
  • 0
  • 0
  • 0.0006459
  • -0.1442
Input
  • 0.00195
  • 0.00001527
  • 0.00009999
  • 0.00001226
  • 0.005349
  • 0
  • 0
  • 0.00004975
  • 0.000008733
  • -0.005262
Output
  • 0.0002445
  • 0.000007363
  • 0.000008436
  • 0.000005915
  • 0.002729
  • 0
  • 0
  • 0
  • 0.004877
  • -0.0003796
Output
  • 0.006439
  • 0.006943
  • 0.0001047
  • 0.005577
  • 2.406
  • 0
  • 0
  • 0
  • 0.02329
  • -0.02555
Output
  • 0.000004154
  • 9.725E-7
  • 1.182E-8
  • 7.812E-7
  • 0.0003328
  • 0
  • 0
  • 0
  • 4.949E-8
  • -0.000002792
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0.001309
  • 0
  • 0.05367
  • 0
  • 0
  • 0.0256
  • 0.000001703
  • -0.0003499
Output
  • 0
  • 0
  • 0.0002909
  • 0
  • 0.004377
  • 0
  • 0
  • 0.0988
  • 2.686E-7
  • -0.00006762
Output
  • 0
  • 0
  • 0.000447
  • 0
  • 0.00901
  • 0
  • 0
  • 0.1711
  • 0.000004694
  • -0.00015
Output
  • 0
  • 0
  • 0.006762
  • 0
  • 0.1363
  • 0
  • 0
  • 2.589
  • 0.00007102
  • -0.00227

IndikatorEinheit Rohstoffbereitstellung
A1
Transport
A2
Herstellung
A3
Transport
A4
Einbau
A5
Abbruch
C1
Transport
C2
Abfallbehandlung
C3
Beseitigung
C4
Recyclingpotential
D
Abiotisk utarmingspotensial for fossile ressurser, fosile brensler (ADP-fossil)
  • 4.006
  • 0.1428
  • 0.001468
  • 0.1147
  • 48.99
  • 0
  • 0
  • 0.01787
  • 0.00771
  • -1.343
Abiotisk utarmingspotensial for ikke-fossile ressurser, mineraler (ADP-elements)
  • 0.00000133
  • 2.608E-7
  • 6.292E-9
  • 2.095E-7
  • 0.00009012
  • 0
  • 0
  • 9.631E-9
  • 3.322E-9
  • -0.00002883
Forsurningspotensial for kilder på land og vann (AP)
  • 0.0005954
  • 0.00002713
  • 8.329E-7
  • 0.0000218
  • 0.009618
  • 0
  • 0
  • 0.0000336
  • 0.000002748
  • -0.005356
Globalt oppvarmingspotensial - biogene kilder( GWP-biogenic)
  • -0.04905
  • 0.000003908
  • 0.0000021
  • 0.000003139
  • 0.05088
  • 0
  • 0
  • 0.000002189
  • 3.578E-7
  • -0.0003089
Globalt oppvarmingspotensial - fossile brensler (GWP-fossil)
  • 0.1335
  • 0.009442
  • 0.0007873
  • 0.007585
  • 3.243
  • 0
  • 0
  • 0.2672
  • 0.002489
  • -0.07725
Globalt oppvarmingspotensial -totalt (GWPtotal)
  • 0.0846
  • 0.009449
  • 0.0007897
  • 0.007591
  • 3.295
  • 0
  • 0
  • 0.2672
  • 0.002489
  • -0.07856
Globalt oppvarmingspotensial arealbruk endringer i bruk av arealer (GWP-luluc)
  • 0.0001008
  • 0.000003361
  • 3.206E-7
  • 0.0000027
  • 0.001155
  • 0
  • 0
  • 3.298E-7
  • 9.957E-8
  • -0.0009984
  • 0.1282
  • 0.009449
  • 0.0007896
  • 0.007591
  • 3.244
  • 0
  • 0
  • 0.2672
  • 0.002507
  • -0.06096
Overgjødslingspotensial til ferskvann (EP-freshwater)
  • 0.000004486
  • 7.543E-8
  • 5.722E-9
  • 6.06E-8
  • 0.00002902
  • 0
  • 0
  • 2.171E-8
  • 6.689E-9
  • -0.00003687
Overgjødslingspotensial til hav (EP-marine), hav og jord
  • 0.0001001
  • 0.000005369
  • 1.649E-7
  • 0.000004313
  • 0.001852
  • 0
  • 0
  • 0.00001609
  • 0.000003165
  • -0.000294
Overgjødslingspotensial til jord (EP-terrestrial)
  • 0.001102
  • 0.00006006
  • 0.000001892
  • 0.00004825
  • 0.02074
  • 0
  • 0
  • 0.0001741
  • 0.00001047
  • -0.004158
Potensial for fotokjemisk oksidantdanning (POCP)
  • 0.0004165
  • 0.00002301
  • 4.996E-7
  • 0.00001848
  • 0.007935
  • 0
  • 0
  • 0.0000418
  • 0.000003401
  • -0.001157
Potensial for nedbryting av stratosfærisk ozon (ODP)
  • 5.061E-9
  • 2.138E-9
  • 1.2E-11
  • 1.718E-9
  • 7.318E-7
  • 0
  • 0
  • 2.08E-10
  • 9.9E-11
  • -0.002026
Utarmingspotensial for vannressurser (WDP)
  • 7.2
  • 0.1381
  • 0.1798
  • 0.1109
  • 47.5
  • 0
  • 0
  • 0.04116
  • 0.08196
  • -6.326

IndikatorEinheit Rohstoffbereitstellung
A1
Transport
A2
Herstellung
A3
Transport
A4
Einbau
A5
Abbruch
C1
Transport
C2
Abfallbehandlung
C3
Beseitigung
C4
Recyclingpotential
D
1Diese Wirkungskategorie behandelt hauptsächlich die mögliche Wirkung einer ionisierenden Strahlung geringer Dosis auf die menschliche Gesundheit im Kernbrennstoffkreislauf. Sie berücksichtigt weder Auswirkungen, die auf mögliche nukleare Unfälle und berufsbedingte Exposition zurückzuführen sind, noch auf die Entsorgung radioaktiver Abfälle in unterirdischen Anlagen. Die potenzielle vom Boden, von Radon und von einigen Baustoffen ausgehende ionisierende Strahlung wird ebenfalls nicht von diesem Indikator gemessen.
2Die Ergebnisse dieses Umweltwirkungsindikators müssen mit Bedacht angewendet werden, da die Unsicherheiten bei diesen Ergebnissen hoch sind oder da es mit dem Indikator nur begrenzte Erfahrungen gibt.
Ioniserende stråling, helseeffekt (IRP) 1
  • 0.004619
  • 0.000624
  • 0.00002036
  • 0.0005013
  • 0.2136
  • 0
  • 0
  • 0.00003078
  • 0.00003822
  • -0.003458
Partikkelutslipp (PM) 2
  • 5.245E-9
  • 5.78E-10
  • 6E-12
  • 4.64E-10
  • 1.984E-7
  • 0
  • 0
  • 1.48E-10
  • 4.5E-11
  • -2.46E-8
Påvirkninger knyttet til arealbruksendringer / jordkvalitet (SQP) 2
  • 4.704
  • 0.09986
  • 0.0007882
  • 0.08022
  • 34.28
  • 0
  • 0
  • 0.002223
  • 0.02511
  • -3.273
Toksisitet påvirkning på mennesker, andre effekter enn kreft (HTP-nc) 2
  • 1.198E-9
  • 1.15E-10
  • 7E-12
  • 9.3E-11
  • 4.47E-8
  • 0
  • 0
  • 2.26E-10
  • 1.3E-11
  • -5.85E-8
Toksisitet påvirkning på mennesker, kreft (HTP-c) 2
  • 3.9E-11
  • 0
  • 0
  • 0
  • 5.9E-11
  • 0
  • 0
  • 6E-12
  • 0
  • -7.02E-10
Økotoksisitet, ferskvann (ETP-fw) 2
  • 2.017
  • 0.1058
  • 0.006391
  • 0.08502
  • 38.76
  • 0
  • 0
  • 0.05304
  • 1.125
  • -48.81